Sleeves in the pumps were changed last night to 6” ...

Sleeves in the pumps were changed last night to 6” and after that up to 65 L/s have been pumped through the string at 225 bar pressure, while pulling with up to 250 tonne for 5 minutes and activating the jar in between. There have been small signs of progress with drops in the standpipe pressure at constant flow rate and the fish appears to have moved upwards slightly.
- Links: